FEATURES:
●Capacity: 15t to 150t
●Material option: Alloy steel
APPLICATION:
●Crane scale
●Hopper scale
●Packing scale
Outline Dimension: |
|||||
Rated capacity |
L1 |
L2 |
B |
D |
H |
15t,20t,30t |
340 |
210 |
130 |
Φ63 |
48 |
50t |
620 |
438 |
171 |
Φ85.5 |
47 |
100t,150t |
500 |
305 |
190 |
Φ97 |
130 |
SPECIFICATION: | |
Rated capacity: 15t to 150ton | Operating temperature range: -30 to +70℃ |
Rated output:2.0±0.002mv/v(15t~50t),1.5±0.002mv/v(100t~150t) | Maximum safe overload;120% OF R.C |
Combined error:±0.05% F.S | Ultimate safe overload;150% OF R.C |
Non-repeatability:±0.03% F.S | Recommended Excitation;10 to 12V DC |
Non-linearity:±0.05% F.S | Maximum Excitation;15V DC |
Hysteresis error:±0.05% F.S | Environment protection: IP67 |
Zero balance: ±1% F.S | Input impedance: 400±20Ω |
Creep error(30minutes): ±0.05% F.S | Output impedance: 352±3Ω |
Temperature effect on zero: ±0.03% F.S | Insulation resistance at 50V DC: ≥5000MΩ |
Temperature effect on output: ±0.03% F.S | Material: nickel-plated alloy steel |
Compensated temperature range: -10 to +40℃ | cable length: 12meter(3t~30t,100t~150t) diameter 5mm,10meter(50t) diameter 8mm |