Outline Dimension: |
|||||||||||||||
Rated capacity |
L1 |
L2 |
L3 |
L4 |
L5 |
L6 |
W1 |
W2 |
W3 |
H1 |
H2 |
H3 |
H4 |
R |
T |
10,15,20,25,30 |
560 |
501 |
272 |
190 |
162 |
31 |
130 |
80 |
26 |
70 |
45 |
28 |
10 |
R13 |
M24 |
Cảm biến lực dùng cho cân tàu hoả
Cảm biến lực dùng cân tàu hỏa (Load cells) BTL – 20T
FEATURES:
●Capacity: 10t to 30t
●Double ended shear beam structure
●Low profile
APPLICATION:
●Railway scale
Tài liệu download: BTL Installation diagram
SPECIFICATION: | |
Rated capacity: 10ton to 30ton | Operating temperature range: -30 to +70℃ |
Rated output:1.6±0.005mv/v | Maximum safe overload;120% OF R.C |
Combined error:±0.3% F.S | Ultimate safe overload;150% OF R.C |
Non-repeatability:±0.05% F.S | Recommended Excitation;10 to 12V DC |
Non-linearity:±0.3% F.S | Maximum Excitation;15V DC |
Hysteresis error:±0.3% F.S | Environment protection: IP67 |
Zero balance: ±1% F.S | Input impedance: 750±10Ω |
Creep error(30minutes): ±0.05% F.S | Output impedance: 703±5Ω |
Temperature effect on zero: ±0.03% F.S/10℃ | Insulation resistance at 50V DC: ≥5000MΩ |
Temperature effect on output: ±0.03% F.S/10℃ | Material: alloy steel |
Compensated temperature range: -10 to +40℃ | cable length: 16meter, diameter 6mm |